ADR codes for industrial waste, explained for EHS managers.
Find the UN number, class and packing group of the waste streams you actually ship — solvents, oils, batteries, aerosols, contaminated packagings — and understand what ADR expects from you as the consignor.
44 waste-relevant UN entries · 6 practical guides · Updated 2026-11-23
Find a UN number for your waste
| UN | Proper shipping name | Class | PG | Typical waste streams |
|---|---|---|---|---|
| UN 1202 | DIESEL FUEL / GAS OIL / HEATING OIL, LIGHT | 3 | III | Generator fuel residues, tank bottoms, contaminated fuel from backup gensets (data centers), maintenance drains |
| UN 1203 | MOTOR SPIRIT (GASOLINE / PETROL) | 3 | II | Fuel drained from vehicles and small engines, contaminated petrol |
| UN 1090 | ACETONE | 3 | II | Spent cleaning solvent, degreasing, lab waste |
| UN 1170 | ETHANOL (ETHYL ALCOHOL) or ETHANOL SOLUTION | 3 | II / III | Disinfectant residues, cleaning, lab and process waste |
| UN 1219 | ISOPROPANOL (ISOPROPYL ALCOHOL) | 3 | II | Electronics cleaning, wipes stations, disinfectant residues |
| UN 1263 | PAINT or PAINT RELATED MATERIAL | 3 | I / II / III | Leftover paints, varnishes, thinners, booth sludge |
| UN 1133 | ADHESIVES containing flammable liquid | 3 | I / II / III | Glue residues, expired adhesive drums |
| UN 1210 | PRINTING INK, flammable | 3 | I / II / III | Ink waste from printing and marking lines |
| UN 1294 | TOLUENE | 3 | II | Spent solvent, coating lines |
| UN 1307 | XYLENES | 3 | II / III | Spent solvent, coating and lab waste |
| UN 1268 | PETROLEUM DISTILLATES, N.O.S. | 3 | I / II / III | Hydrocarbon mixtures, cutting fluid concentrates with low flash point |
| UN 1993 | FLAMMABLE LIQUID, N.O.S. | 3 | I / II / III | Mixed solvent waste, unknown flammable effluents |
| UN 1950 | AEROSOLS | 2 | — | Used spray cans, lubricant and paint aerosols, cans 'never quite empty' |
| UN 1978 | PROPANE | 2 | — | Gas cylinders, forklift bottles |
| UN 1078 | REFRIGERANT GAS, N.O.S. | 2 | — | Recovered refrigerant from HVAC/CRAC units |
| UN 3159 | 1,1,1,2-TETRAFLUOROETHANE (R-134a) | 2 | — | Recovered refrigerant from chillers and cooling units (data centers, plants) |
| UN 1789 | HYDROCHLORIC ACID | 8 | II / III | Pickling baths, descaling, lab acids |
| UN 1830 | SULPHURIC ACID, with more than 51% acid | 8 | II | Spent acid, battery electrolyte, surface treatment |
| UN 1823 | SODIUM HYDROXIDE, SOLID | 8 | II | Caustic residues, cleaning-in-place chemicals |
| UN 1824 | SODIUM HYDROXIDE SOLUTION | 8 | II / III | Spent caustic, CIP solutions, degreasing baths |
| UN 1760 | CORROSIVE LIQUID, N.O.S. | 8 | I / II / III | Mixed corrosive effluents |
| UN 1759 | CORROSIVE SOLID, N.O.S. | 8 | I / II / III | Corrosive sludges, salts, contaminated absorbents |
| UN 3264 | CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. | 8 | I / II / III | Acid mixtures from surface treatment and electroplating |
| UN 3266 | CORROSIVE LIQUID, BASIC, INORGANIC, N.O.S. | 8 | I / II / III | Alkaline baths, mixed basic effluents |
| UN 2014 | HYDROGEN PEROXIDE, AQUEOUS SOLUTION | 5.1 | I / II / III | Disinfection, bleaching, cleanroom chemistry |
| UN 2810 | TOXIC LIQUID, ORGANIC, N.O.S. | 6.1 | I / II / III | Toxic process residues, lab waste |
| UN 2811 | TOXIC SOLID, ORGANIC, N.O.S. | 6.1 | I / II / III | Toxic solid residues, contaminated filters |
| UN 3175 | SOLIDS CONTAINING FLAMMABLE LIQUID, N.O.S. | 4.1 | II | Solvent-soaked rags, wipes, absorbents, paint-contaminated solids |
| UN 1325 | FLAMMABLE SOLID, ORGANIC, N.O.S. | 4.1 | II / III | Resin and powder residues |
| UN 2794 | BATTERIES, WET, FILLED WITH ACID | 8 | — | Lead-acid batteries from forklifts, vehicles, older UPS strings |
| UN 2795 | BATTERIES, WET, FILLED WITH ALKALI | 8 | — | Ni-Cd / alkaline wet cells from industrial backup |
| UN 2800 | BATTERIES, WET, NON-SPILLABLE | 8 | — | VRLA batteries from UPS systems (data centers, plants) |
| UN 3480 | LITHIUM ION BATTERIES | 9A | — | Used Li-ion packs, scooters, tools, battery energy storage modules |
| UN 3481 | LITHIUM ION BATTERIES CONTAINED IN / PACKED WITH EQUIPMENT | 9A | — | Laptops, servers, handhelds, IT assets at end of life |
| UN 3090 | LITHIUM METAL BATTERIES | 9A | — | Primary lithium cells, RTC/backup coin cells in bulk |
| UN 3091 | LITHIUM METAL BATTERIES CONTAINED IN / PACKED WITH EQUIPMENT | 9A | — | Equipment with primary lithium cells |
| UN 3077 | ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. | 9 | III | Contaminated soils, sludges, filter cakes, heavy-metal residues |
| UN 3082 | ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. | 9 | III | Used oils and emulsions, coolant/cutting fluids, oily water when ecotoxic |
| UN 2315 | POLYCHLORINATED BIPHENYLS, LIQUID | 9 | II | Old transformer and capacitor oils |
| UN 3432 | POLYCHLORINATED BIPHENYLS, SOLID | 9 | II | PCB capacitors, contaminated equipment |
| UN 2590 | ASBESTOS, CHRYSOTILE | 9 | III | Demolition and refurbishment waste (white asbestos) |
| UN 2212 | ASBESTOS, AMPHIBOLE | 9 | II | Blue/brown asbestos from demolition |
| UN 3509 | PACKAGINGS, DISCARDED, EMPTY, UNCLEANED | 9 | — | Empty drums, IBCs and cans with residues of dangerous goods |
| UN 3291 | CLINICAL WASTE, UNSPECIFIED, N.O.S. | 6.2 | II | Infectious waste from on-site medical units and labs |
Data shown for orientation only. Always confirm against Table A of chapter 3.2 of the current ADR edition (ADR 2025) and validate with your Dangerous Goods Safety Adviser (DGSA).
What EHS managers struggle with
We interviewed EHS/QSE managers in manufacturing plants and data centers and analysed the questions they ask online. The same five jobs come back.
Classify mixed waste correctly
Solvent mixes, sludges, absorbents: no single entry fits. You must pick the right N.O.S. entry and packing group — and justify it. Method →
Reconcile waste codes and UN numbers
The waste register speaks EWC codes, the truck speaks UN numbers. Two ledgers for one load, rarely kept in sync. Explained →
Know when full ADR applies
Limited quantities, the 1.1.3.6 '1000 points' rule or full ADR — the answer changes the paperwork and the cost of each pickup. Calculate →
Stay responsible without being the expert
You rely on your contractor and DGSA, but as consignor the liability stays with you. You need proof, not assumptions. Who does what →
Report across sites without spreadsheets
Invoices, manifests and registers live in PDFs and emails. Consolidating them for audits and ESG reporting eats days every quarter. See how Wastetide does it →
Ship under DOT and ADR
Global groups run US plants under 49 CFR and EU plants under ADR. Same UN logic, different rules. Compare →
Turn your ADR waste data into a clean, audit-ready inventory
Upload your waste invoices, manifests and registers. Wastetide's AI extracts every stream — waste code, UN number, volumes, costs — and flags inconsistencies for your DGSA to review. No change to your operations.
Frequently asked questions
What is an ADR code?
"ADR code" usually refers to the identifiers used under the ADR agreement for road transport of dangerous goods: the four-digit UN number, the proper shipping name, the hazard class, the packing group (I, II or III) and the tunnel restriction code. Together they appear on the transport document, e.g. UN 1263 WASTE PAINT, 3, II, (D/E).
Does ADR apply to waste?
Yes. Waste that meets the criteria of one of the ADR hazard classes is a dangerous good until it is disposed of. It is classified, packed, labelled and documented like any other dangerous good, and the word WASTE is added before the proper shipping name on the transport document.
What is the difference between a waste code (EWC/LoW) and a UN number?
They answer two different questions. The European waste code (6 digits, with an asterisk if hazardous) describes what the waste is and drives the environmental obligations. The UN number describes how the waste may travel by road. A hazardous waste code does not automatically make a waste ADR-regulated, and a non-hazardous waste code does not exempt it if it meets ADR criteria. You need both, stream by stream.
Who is responsible for classifying waste under ADR?
The consignor — in practice the waste producer handing the waste over for carriage. Your waste contractor or DGSA can help, but the consignor remains responsible for the classification (ADR 1.4.2.1).
How do I classify a waste whose composition is not exactly known?
ADR 2.1.3.5.5 allows classification based on the consignor's knowledge of the waste and available technical and safety data (SDS section 14, waste identification sheets, analyses). Choose the most specific collective (N.O.S.) entry, take the highest degree of danger, and add 'WASTE IN ACCORDANCE WITH 2.1.3.5.5' on the transport document. Packing group III is not allowed under this route, except for UN 3077 and UN 3082.
Do I need a Dangerous Goods Safety Adviser (DGSA)?
Under ADR 1.8.3, any undertaking whose activities include consigning, packing, loading, filling, unloading or carrying dangerous goods must appoint a safety adviser, subject to national exemptions. Since ADR 2019, consignors are explicitly covered. The DGSA produces an annual report and monitors compliance.
Further reading
From the Wastetide blog
- ADR 2027: what changes on 1 January 2027 for hazardous waste and battery shipments — New battery UN numbers, damaged-battery paperwork, eased rules for empty drums, IBCs and used equipment. Mandatory from 1 July 2027.
- The end of paper hazardous waste manifests: what EPA's paper sunset rule means for EHS teams — EPA wants to retire paper manifests 24 months after its final rule, while electronic manifests are still under 1% of submissions.
- EU Waste Shipment Regulation 2024/1157: what changes for cross-border industrial waste — Applies since 21 May 2026: digital procedures in DIWASS, stricter contracts, a ban on shipments for disposal and plastic export limits.
- Lithium-ion UPS batteries: what EPA's coming universal waste rule means for data center EHS teams — EPA is drafting a dedicated universal waste category and the House passed the BRACE Act. What EHS managers should do now.
More free references by Wastetide: US hazardous waste map (urbanmines.us) · Secondary Materials Terminal (secondarymaterials.ai) · Data Center Waste Map (datacenterwaste.us)